Kurulum & Lisanslama Merkezi
Ansys Download & Installation Guide (Start Here!)
Authored by Erdoğan Gökbulut November 21st, 2024 905 views 1 likes KB2403120
Description
Ansys software requires several simple, but unique, steps to install correctly. Our detailed, but easy to follow instructions will help you download and install your Ansys software and ensure your installation is a success!
Solution
Windows
Flagship Ansys Products
Step #1 - Preparation & Requirements
Tip
Skip straight to the Step #5 if you already have a license server deployed in your organization AND it's running the latest version (the latest version should always be used and is fully backward compatible).
- Obtain access to the license server computer.
- Two applications are required to use Ansys - the License Manager and the Client Software.
- In multi-user deployments, the license manager should be installed on a dedicated computer and NOT on the client computer.
Deployment Methods
Step #2 - Obtain Your License File
- If you haven't already obtained your license file, please do so now.
Step #3 - Download the Software
-
Login to the Customer Portal
- First, Sign up for access to the Customer Portal if you have not already done so.
- Login to the Ansys Customer Portal > Select Downloads > Current Release > expand the Tools section.
-
Download the License Manager (~400MB)
-
Download Client Software Package of your choice
- Primary Packages: If you only need to install a single physics package, downloading the primary package (zip file) is normally easiest as the download is smaller.
-
ISO Images: If you are installing multiple physics packages, we recommend downloading the ISO files because these files include all physics packages (excluding Electronics) which makes installation faster.
Step #4 - Install the License Manager
Warning
These steps must be performed on the computer that your license file was issued to when you Gathered License Server Host Info. You are not able to install a license on any other machine other then the one it was issued to.
Upgrading?
- The steps to install and upgrade the license manager software are the same.
- If upgrading, the existing license file (& option file if applicable) will remain and a license does not need to be installed unless you have received a newer license.
- It is not possible to run multiple versions of the license manager on the same machine.
-
Prepare the Installation Files
- Unzip the file:
- Right click the file > select Extract All. (If the setup file is run without unzipping the archive file first, the installation will appear to complete successfully, but the program will not function properly)
- Unzip the file:
Don't miss these steps!
* Skipping these steps won’t always produce error messages during the installation, but unfortunately can still corrupt the install and cause various software errors.
-
Install the Software
- Once the file has been unzipped, right click the setup.exe file > Run as Administrator
Note: Be aware that the license manager will be stopped during the installation and clients will not be able to communicate with the license server during this time. The installation typically takes ~ 5min. - Follow the prompts to complete the installation. Default values are recommended unless there is a specific reason that requires otherwise.
- Upon completing the installation, the License Management Center web page will open:
- Once the file has been unzipped, right click the setup.exe file > Run as Administrator
-
Add Required Firewall Exceptions
- You must add firewall exceptions to your firewall in order for other client computers to communicate with your license server.
Step #5 - Install your License File(s)
Always Update Your License Manager
Outdated License Manager Software is a very common cause of license checkout related issues. Newer versions of the license manager are backward compatible.
- Install Your License File(s)
- Set a static Vendor Daemon Port
-
Communicate License Server Name to Your Users
- They will need to specify the server name (not IP address) in the client license settings.
- Send all users these instructions along with your server name.
Step #6 - Install Client Software
Always Update Your License Manager
Outdated License Manager Software is a very common cause of license checkout related issues. The License Manager is backward compatible with previous licenses and versions.
Note
- Installing a newer version of the client software does not remove older versions. All versions installed on a computer can be used simultaneously.
- If multiple versions of Ansys need to be installed, the most recent version must be installed last, otherwise Ansys licensing & checkout will not work properly. If you need to install an older version and already have a newer version installed, reinstall the latest version after installing the older version(s).
-
Prepare the Installation Files
-
If you downloaded a Primary Package / Zip File:
- Unzip the file by right clicking it and selecting Extract All. (If the setup file is run without unzipping the file first, the installation will appear to complete successfully, but the program will not function properly)
-
If you downloaded the ISO Images:
- Double click the Disc 1 ISO file. This will mount it as a virtual DVD drive in Windows 10.
- Browse to and double click all other ISO files, this will mount them as an additional virtual DVD drive. (Take note of the drive letter is used for each disk as this will be used later)
-
If you downloaded a Primary Package / Zip File:
-
Install the Software
- Right click the setup.exe file found with your installation files and select Run as Administrator.
- When prompted, specify the name of the license server you will be using.
- Follow the installation wizard, selecting the software packages applicable to you.
- Allow the installation to complete. This normally takes anywhere from 10-30 min, depending on how many applications you are installing and the speed of the computer.
-
Specify a License Server
- Lastly, Specify a License Server to connect to if you did not do so during the installation wizard.
- If you can't checkout licenses, see HOW TO - Test & Fix License Manager Connectivity Issues
Step #7 - Install Service Packs (Optional)
If the version you have installed has any available service packs, they will be listed at the bottom of the Ansys Software Download Center:
NOTE: You can sign up to receive email notifications when service packs become available. Click here to sign up.
Other Products
LSTC Software - LS-Dyna & Others
-
Download & Install the License Manager
- These steps must be performed from the computer which will be your license manager.
- Download the LSTC License Manager
- Username: user
- Password: computer
- Follow the License Manager Installation Instructions (Windows)
- Make sure you right click the installation file and select Run as Administrator.
-
Download & Install the Client Software
- Follow LSTC Download and Installation Instructions
- FTP Credentials
- Username: user
- Password: computer
Rocky
-
Receive Welcome Email with License File
- This will enable your access to the ESSS Customer Portal
- Sign In to the ESSS Customer Portal
-
Install the License Manager
- Navigate to Technical Content > ROCKY > Installation & Setup
- Follow “Install and Configure FlexLM Server” (Windows) document.
-
Install the Rocky client application
- Follow “How to Install” (Windows) document in the customer portal
nCode - 2021 R2 & Later
Installing Ansys nCode can vary depending on the version you need. In 2021 R2, it is bundled with the Ansys suite and no longer requires a separate download.
- Follow Steps #1-3 above for Flagship Ansys Products.
- In Workbench, click on Extensions > ACT Start Page > Manage Extensions
- Find the MechanicalEmbeddedDesignLife extension in the list, then click the down arrow and Load as Default
- When returning to the project, you'll see nCode DesignLife in the Toolbox
nCode - 2021 R1 & Prior
Info
These instructions are written using 2021 R1 as an example and uses the corresponding file names, please find the appropriate file names for your version.
- Follow Steps #1-3 above for Flagship Ansys Products.
- In the Ansys Customer Portal, download the nCode package from the Add-On Packages section.
Info
For more information about accessing the Ansys Customer Portal, check out Accessing the Ansys Customer Portal
- Extract NCODE_2021R1_WINX64.zip, and open the resulting NCODE_2021R1_WINX64 folder
- Extract the nCode2020P1_Ansys2021R1_Release_Build350_Win64.zip folder, and open the resulting folder
- Right click on setup.exe and choose Run as Administrator
- Click Next through the wizard to agree to the license terms, choose a language, and then click Install to start the installation.
- Open Ansys Workbench, and click on Extensions > Install Extension
- Navigate to the NCODE_2021R1_WINX64 folder, and select the MechanicalEmbeddedDesignLife.wbex, and choose Open.
- In Workbench, click on Extensions > ACT Start Page > Manage Extensions
- Find the MechanicalEmbeddedDesignLife extension in the list, then click the down arrow and Load as Default
- When returning to the project, you'll see nCode DesignLife in the Toolbox
Linux
Flagship Ansys Products
Step #1 - Gather Important Info
Tip
Skip straight to the Step #4 if you already have a license server deployed in your organization AND it's running the latest version (the latest version should always be used and is fully backward compatible).
- Two applications are required to use Ansys - the License Manager and the Client Software.
- In multi-user deployments, the license manager should be installed on a dedicated computer and NOT on the client computer.
- Obtain access to the license server computer.
- Obtain your license and have it on hand if you will be installing a new license.
Deployment Methods
Step #2 - Download the Software
-
Login to the Customer Portal
- First, Sign up for access to the Customer Portal if you have not already done so.
- Login to the Ansys Customer Portal > Select Downloads > Current Release > expand the Tools section.
-
Download the License Manager (~400MB)
-
Download Client Software Package of your choice
- Primary Packages: If you only need to install a single physics package, downloading the primary package (zip file) is normally easiest as the download is smaller.
-
ISO Images: If you are installing multiple physics packages, we recommend downloading the ISO files because these files include all physics packages (excluding Electronics) which makes installation faster.
Step #3 - Install the License Manager
These steps must be performed on the computer that your license file was issued to when you Gathered License Server Host Info.
Upgrading?
- The steps to install and upgrade the license manager software are the same.
- If upgrading, the existing license file (& option file if applicable) will remain and a license does not need to be installed unless you have received a newer license.
- A client cannot checkout a license from a server running a version older than the client software. In this case, the license server must be updated to the newest version.
- It is not possible to run multiple versions of the license manager on the same machine.
- Install Required Linux Packages & Libraries
-
Prepare the Installation Files
- Unzip the file:
-
Right click the file > select Open with Archive Manager > Extract > select the desired folder to extract the files > Extract
-
Right click the file > select Open with Archive Manager > Extract > select the desired folder to extract the files > Extract
- Unzip the file:
-
Install the Software
- Once the files have been extracted > select Show the Files > Right click in the blank folder space, not a file > select Open in Terminal > type the install command: [user@ localhost folder]$ ./INSTALL
- Follow the prompts to complete the installation. Default values are recommended unless there is a specific reason that requires otherwise.
- Upon completing the installation, the License Management Center web page will open:
- Once the files have been extracted > select Show the Files > Right click in the blank folder space, not a file > select Open in Terminal > type the install command: [user@ localhost folder]$ ./INSTALL
-
Add Required Firewall Exceptions
- You must add firewall exceptions to your firewall in order for other client computers to communicate with your license server.
Step #4 - Install your License File(s)
Always Update Your License Manager
Outdated License Manager Software is a very common cause of license checkout related issues. The License Manager is backward compatible with previous licenses and versions.
- Install Your License File(s)
- Set a static Vendor Daemon Port
-
Communicate License Server Name to Your Users
- They will need to specify the server name (not IP address) in the client license settings.
- Send all users these instructions along with your server name.
Step #5a - Install Client Software
Always Update Your License Manager
Outdated License Manager Software is a very common cause of license checkout related issues. The License Manager is backward compatible with previous licenses and versions.
- Install Required Linux Packages & Libraries
- Install Client Software
Step #5b - Install Electromagnetics (if applicable)
Always Update Your License Manager
Outdated License Manager Software is a very common cause of license checkout related issues. The License Manager is backward compatible with previous licenses and versions.
Other Products
LSTC Software - LS-Dyna & Others
-
Download & Install the License Manager
- These steps must be performed from the computer which will be your license manager.
- Download the LSTC License Manager
- Username: user
- Password: computer
- Follow Instructions the License Manager Installation Instructions (Linux)
-
Download & Install the Client Software
- Follow LSTC Download and Installation Instructions
- FTP Credentials
- Username: user
- Password: computer
Rocky
-
Receive Welcome Email with License File
- This will enable your access to the ESSS Customer Portal
- Sign In to the ESSS Customer Portal
-
Install the License Manager
- Navigate to Technical Content > ROCKY > Installation & Setup
- Follow “Install and Configure FlexLM Server” (Linux) document.
-
Install the Rocky client application
- Follow “How to Install” (Linux) document in the customer portal
Experiencing Errors?
- Search our KB for your error message
- Common Quick Fix - HOW TO - Reset Ansys Settings to Default
- Can't connect to the license server? - HOW TO - Test & Fix License Manager Connectivity Issues
- Can't checkout a license? - HOW TO - Verify Licenses Can be Checked Out
- Did reinstalling Ansys not work? - Perform a Comprehensive Reinstall of Ansys
- Other problems? - Ansys Troubleshooting Guide